Category:HamsterProKit
From cogniteam
Contents
AAEON Pro Kit support page
3rd party things need to know to work with kit
- ROS general information: WHAT IS ROS
- ROS2 general information: ROS2
- RVIZ - instrument for visualization: RVIZ
Kit prerequisite (not included in the kit)
- Lipo battery with T connector 7.4V 2 cell.
- Battery charger
1. Connecting all parts within the kit
- Use the LLC cable (in the picture) to both monitor and charge the battery
* Port 9 can be used to charge the Lipo Battery * Port 8 should connect the the Lipo battery balancer (JST connector) * Port 7 should connect to the LLC board * Red T connector (rightmost on the picture)
- Connect the Up Squared board to the LLC as shown in the picture
* TX/RX should be connected to GPIO ports * Power should be connected through DC connector
- Connect the MX2 wifi module
- Connect the two WIFI antennas using the SMT connector to the integrated chip
- Connect the Movidius chip using the PCI connector
- Connect the D435i camera to a USB3 Port using the cable
Note: Camera D435i must be already updated with latest firmware and have calibrated IMU. Visit official site for more information.
2. Run installation script
Internet connection requires
Download installation script:
Copy to home directory and give permissions:
cp /home/devkit/Downloads/installation.sh .
sudo chmod +x installation.sh
Run script:
./installation.sh
Reboot board after installation.
3. Configure ROS IP
Configure IP for ROS applications:
pico hamster.config
in home directory
Edit row with your board IP:
export HAMSTER_IP=your_IP
4. Launch examples
To run examples in ROS run command:
ros_prokit
To run example in ROS2 run command:
ros2_prokit
Subcategories
This category has the following 4 subcategories, out of 4 total.